PC9155 Wireless Alarm System
5-43
[804][320] Global Siren Options
[804][330] WT4911 Maximum Bell Activation Time
This value determines the maximum time the wireless bell/siren will sound before automatically turning off.
[804][900] General Wireless Options
[851] GPRS/Ethernet Module Programming
Refer to the associated manual for programming details.
[898] Wireless Device Enrolment
See Chapter 2 for details.
[899] Template Programming
See Chapter 4 for details.
[900] Alarm System Version
When this section is entered the version of the panel is displayed as a 4-digit decimal entry.
E.g., The entry 1234 = Version 12.34. This is a read-only value.
[904] Wireless Module Placement Test
See Chapter 2 for details.
[905] Wireless Keypad Placement Test
See Chapter 2 for details.
[906] Wireless Siren Placement Test
See Chapter 2 for details.
[990] Installer Lockout Enable
This feature is designed to prevent installers other than the original from resetting the panel. If enabled, the panel gives a distinctive audible indication on power up
(the phone line relay will click 10 times). If a hardware default is attempted while lockout is enabled, the default does not occur and the false default attempt is
logged to the event buffer. This feature has no effect on a software default (all programming returns to the factory defaults).
[991] Installer Lockout Disable
This section disables the Installer Lockout feature described above.
[992] TL/GS Module Label Broadcast
This section allows the installer to broadcast the partition and zone labels stored in the panel to the GPRS/Ethernet module SMS label programming sections. Press
* to boradcast the labels or # to exit the section. An error tone is sounded if the GPRS/Ethernet module is disabled (section [382] option 5) or is not present.
Note: This feature is only available on WT5500 v1.1 and up keypads.
[998] Restore Panel Default Programming
All programming in the PC9155 returns to the factory defaults, except for the Wireless Device Programming sections.
[999] Restore Factory Default Programming
All programming, including wireless device programming, returns to the factory defaults.
When these options are enabled or disabled, they affect all wireless sirens on the system.
Option Description
[1]
ON: Tamper While Disarmed Activates Siren / Strobe. When the system is in a disarmed state, a tamper condition from any enrolled siren causes
the system sirens and strobes to activate.
OFF: Tamper While Disarmed Doesn’t Activate Siren / Strobe. When the system is in a disarmed state, a tamper condition from any enrolled siren
will not cause the system sirens and strobes to activate.
[2]
ON: Pre-Alarm Signal Enabled. When the system begins entry delay the entry delay time is sent to the wireless siren. If the wireless siren does not
receive a disarm command during the entry delay time, the siren will go into alarm.
OFF: Pre-Alarm Signal Disabled. When the system begins entry delay no entry delay time is sent to the wireless siren. The siren will not go into
alarm until it receives a signal from the panel to tell it to go into alarm.
[3]-[8]
For Future Use
When these options are enabled or disabled, they affect all wireless devices on the system.
Option Description
[1]-[6]
For Future Use
[7]
ON: RF Jam Disabled. RF Jam conditions will NOT be detected, displayed and communicated.
OFF: RF Jam Enabled. RF Jam conditions will be detected, displayed and communicated.