PC9155 Wireless Alarm System
4-2
Digit 1 selects one of the following zone definition options for the first 8 zones. A ‘0’ in the digit 1 location
indicates that the default settings for the first 8 zones are in place unless overridden during enrollment. See section [001] for defaults.
Step
2
Once in the programming section, the 4-digit number “0111” is displayed. Enter
to accept the existing default programming.
See the tables below for details of Digit 1, 2, 3 and 4.
Step
3
After entering ‘0001’, the first telephone entry is dis played. Enter the monitoring station
telephone number after the “D”. Do NOT delete a ny of the remaining “Fs
E.g., To enter 02-1234-5678:
Press followed by
to complete the entry. See section [301] for additional details.
Step
4
After programming the first telephone number, the system account code is displayed.
The system account code can be any 6-digit combination of numbers (0-9) and letters (A-
F). If the system account code is 4-digits, the last two digits must be ‘FF’.
To enter the letters A through F, press then the numbers 1 through 6 for the letter A
through F respectively. Press again to revert back to decim
al entry.
E.g.,: To enter “1234FF” Press .
See section [310] for additional details.
Step
5
After programming the system account code, the downloading access code is displayed.
Enter the new downloading access code or press to proceed to the next step. See
section [403] for additional details.
Step
6
The entry delay is the amount of time given to disarm the alarm system, after entering the
premises through a delay type zone, before an alarm is sounded.
• Press to accept the default time of 30 seconds (030) or enter an entry
delay between 001 and 255.
E.g., Press 020 for a delay of 20 seconds. See section [005] for additional details.
Step
7
The exit delay is the amount of time given to exit the premises after pressing the Arm key
before the alarm system is armed.
• Press to accept the default time of 120 seconds (120) or enter an entry
delay between 001 and 255.
E.g., Press 030 for a delay of 30 seconds. See section [005] for additional details.
Step
8
After programming the exit delay, the installer code is displayed. Enter a 4 or 6-digit code
depending on the value in section [701] option 5.
Press to exit Template Programming.
See section [006] for installer code details.
Option Zn1 Zn2 Zn3 Zn4 Zn5 Zn6 Zn7 Zn8 Zone Definitions (Options 1- 7)
0 This entry will not change the currently programmed zone definitions.
1 01 03 03 03 04 04 04 04 01 Delay 1
2 01 03 03 05 05 05 05 88 02 Delay 2
3 01 03 03 05 05 05 05 87 03 Instant
4 01 01 03 03 03 03 03 03 04 Interior
5 01 03 03 06 05 05 05 05 05 Interior Stay/Away
6 01 03 03 06 05 05 05 88 06 Delayed Stay/Away
7 01 01 06 06 06 01 01 01 87 Delayed 24 Hr.
Refer to Chapter 5 for zone definition details 88 Standard 24 Hr. Fire
Enter Data
1110
D FFFFFFFFFFFFFF
FFFFFFFFFFFFFFFF
F
D0212345678 FFFF
FFFFFFFFFFFFFFFF
F
,
,
,
Enter Hex Data
FFFFFF
Enter Hex Data
1234FF
Enter Hex Data
155009
Enter Data
300
Enter Data
201
Enter Data
5555