PC9155 Wireless Alarm System
5-32
[167] GPRS/Ethernet Interface Communications Wait for ACK
[168]-[169] Daylight Saving Time
[170] PGM Output Timer
[176] Cross Zone/Police Code Timer
[190] No-Activity Arming Pre-Alert Timer
[191] No-Activity Timer
[202]-[206] Zone Assignments
This value represents the time the communicator waits for an acknowledgement (ACK) from the receiver after sending the SIA packet to the central station.
These sections provide support for programming the beginning and the ending of daylight-saving time. In section [168] the month is programmed in the first entry,
the week in the second entry, and the day of the month or the day of the week in the third entry. The hour of the day when the panel code shall “spring” forward the
system clock with the number of hours is programmed in the last entry of this section. Under section [169] following the order of the entries of section [168] the
installer can program the month, week, day of month or day of week and the hour of the day when the system clock shall “fall” back with the number of hours pro-
grammed in the last entry of this section.
[1] Month Valid entries are 01-12 for January to December.
[2] Week Valid entries are 0-5.
Enter ‘0’ to program a specific date and time to set the clock ahead under section [168] or set the clock back under section [169].
Enter 1-5 to program the occurrence in the month in which the programmed ‘specific day of the week (Sun-Sat)’ will occur to set the
clock ahead under section [168] or back under section [169].
[3] Day If ‘0’ is programmed in the previous section, valid entries are 1-31 for the day of the month.
If ‘1-5’ is programmed in the previous section, valid entries are 0-6 (Sun-Sat) for the day of the week.
[4] Hour Valid entries are 0-23 hours. This is the time of day to advance or set back the clock.
[5] Time Valid entries are 1 or 2 hours. This is the number of hours to advance or set back the clock.
i
To program the last week of the month, program week 5 under the second entry
The time cannot be programmed to change at midnight. If daylight-saving occurs at midnight, program the hour for 2:00 AM
This value represents the period of time (in seconds) that a PGM will activate if programmed to follow the PGM timer. Valid entries are 001-255.
i
If a System Event PGM is programmed to follow the Command Output timer, all PGM attributes do not have to be enabled. The System Tamper will
also follow this timer.
This option affects the Cross Zone/Police Code log and transmission as well as the Cross Zone feature. When a zone trip occurs, the Cross Zone timer starts. This
timer affects the panel in two different ways depending on the programming of the Burglary Verification options (section [016], Option [1]):
If the Police Code feature is being used, the first zone alarm will immediately transmit. When a second zone alarm occurs within the time period (in minutes) pro-
grammed in this section, the panel will log and transmit the Police Code event. If the second zone alarm occurs after this timer expires, the Police Code will not be
logged or transmitted, and the timer will be started again.
If the Cross Zone attribute is used, the first zone alarm will not log, transmit or begin an audible alarm sequence. If a second zone is violated within the Cross Zone
timer's duration (in seconds), the panel goes into the appropriate alarm sequence and communicates both zone alarms followed by the burglary verified signal.
If 000 is programmed in this section, either:
The Police Code transmits for any two different zone alarms during an armed to armed period.
The Cross Zoning feature will not work. This is not a valid entry for Cross Zoning.
i
The Police Code timer is in minutes. the Cross Zone timer is in seconds.
This is the duration which the No-Activity Arming pre-alert sounds when the No-Activity timer expires (see section [191]). The keypad displays System Arming
in Progress for the duration of the pre-alert timer. If programmed as 000, the system arms when the No-Activity timer expires. Valid entries are 000 - 255 minutes.
The system begins its Auto-arm sequence when the No-Activity timer expires. If ‘000’ is programmed in this section, No-Activity Arming is disabled. Valid entries
are from 005 - 255 minutes, 000 to disable. The No-Activity timer starts when an Entry/Exit point is violated. The timer will cancel on the next zone violation and
only start up again when another Entry/Exit point violation occurs.
i
The valid entries begin at 5 minutes. A PIR that is activated cannot be re-activated for at least another 3 minutes.
These sections determine if each individual zone is enabled or disabled. If a zone is enabled, it is supervised by the system and operates according to the zone type
programmed. If a zone is not assigned to the system, it is not supervised and all activity on the zone is ignored by the panel.