PC9155 Wireless Alarm System
2-5
Enrolling Additional Keypads, Sirens & Wireless Keys
1. Enter [ ][8][5555][898]. The following is displayed: “Wireless Enrollment Mode.”
2. Activate the device as indicated below or in the device’s installation sheet.
Additional keypad: Press the [
] and [1] keys simultaneously.
Siren: Power up the device, press the tamper button or the test button to enroll.
Wireless key: Press any key to activate. To re-enroll on another system, press and hold and simultaneously for 3 seconds.
The Electronic Serial Number (ESN) is displayed on the keypad.
•Press [] to confirm the ESN.
If the ESN is incorrect press [#] then repeat this step.
3. After successful confirmation of the ESN, the system prompts for the slot number.
The next available slot is displayed. Press [
] to accept or enter 01-04 for keypads and sirens or 01-16 for wireless keys.
To re-enroll a wireless key press simultaneously for approximately 3 seconds.
Enrolling Sensors & Pendants
1. Enter [ ][8][898]. The LCD displays the following: “Wireless Enrollment Mode.”
2. Place the wireless device in the desired location.
3. Activate the device as described in the associated installation sheet. The electronic serial number (ESN) is displayed.
NOTE: The ESN is a 6-digit alphanumeric number located on a removable sticker on the wireless device.
4. Press [
] to confirm the serial number. If the serial number is incorrect, press [#] and repeat this step. After successful confirmation of the
serial number, the system prompts for the zone number. The next available zone is displayed.
5. Enter a zone number (01-32) then press [ ] to accept. For the first device, enter 01.
NOTE: Only one device may be enrolled in each zone. If a zone already has a device enrolled, press [*] to overwrite the zone or [#] to enter
another zone number. Press [
] to overwrite the zone or [#] to re-enter the zone number.
6. After successful entry of the zone number, the system prompts for the zone type. (The recommended zone type is displayed). Press [ ] to
accept the zone type or:
Enter [01] for Delay type 1 - Entry/Exit Point (e.g., door).
Enter [03] for Instant type (e.g., window).
Enter [05] for Interior Stay/Away type (e.g., motion detector).
Enter [87] for Delayed 24hr. Fire (e.g., smoke detector).
Enter [16] for 24hr. Panic (e.g., panic pendant).
7. After successful entry of a valid zone type, the PC9155 automatically enters individual placement test mode for the zone that was enrolled.
“Activate Device for Test, Exit # ” is displayed on the screen. The device may now be placement tested. See below for details.
8. Press the [#] key to return to the quick enroll screen. Repeat the above procedure for the next zone.
Enrolling Proximity Tags
If this function is available on the keypad, the [ ][5] menu provides the option to assign a proximity tag to an access code once the access code
has been entered. Swipe the tag to enroll it during user access code assignment.
2.4 Wireless Device Placement Test
Perform wireless device placement testing on keypads, sirens and sensors only.
This test is NOT required for wireless keys or pendants. Verify that pendants and wireless keys operate within the desired operating area by
arming and disarming the system.
Test each wireless device multiple times to ensure the location is GOOD.
If a device tests BAD, reposition it and test again. A slight change in placement can cause significant differences in signal strength and range of
a wireless device.
Wireless Receiver Placement Test
The PC9155 includes a wireless receiver placement test feature that indicates the presence of external interference near the alarm panel. This test
activates automatically when in placement test mode [904],[905]or[906]). During a placement test, ensure the yellow LED on the panel is OFF
before placement testing wireless devices. This indicates that the panel is in a location with low interference. If the yellow LED is ON, high levels
of interference are present and the panel should be repositioned.
Wireless Zone Placement Test
1. To placement test a zone, press [][8][XXXX][904]. [XXXX] represents the installer code. The LCD displays the following: “Select Device
for Test < >.”
2. To perform a placement test on an individual zone, type the 2-digit zone number (01 to 32).
i
Before enrolling additional wireless devices, ensure the wireless receiver is located in an area with low interference. See “Wireless
Receiver Placement Test” below for details.